RedNet 3, 5, 6, D16 AES, D16R (MkII), A8R, A16R (MkII), HD32R and D64R - optional termination
The termination on word clock inputs on RedNet 3, 5, 6, D16 AES, D16R (MkII), A8R, A16R (MkII), HD32R and D64R is user-controllable from RedNet Control - you can terminate or un-terminate the word clock input for those devices from the tools menu in RedNet Control.
Red 4Pre, 8Pre, 8Line and 16Line - terminated
The word clock inputs on Red Range are terminated so an additional 75-ohm terminating resistor is not required for proper use.
ISA ADN Cards - optional termination
The termination on word clock inputs on the ISA ADN2 and ISA ADN8 is user-controllable from RedNet Control - you can terminate or un-terminate the word clock input for those devices from the tools menu in RedNet Control.
ISA (Discontinued) Digital Cards
The word clock input on the ISA 2-channel digital card (ISA One + ISA 430) is terminated.
The word clock input on the ISA 8-channel digital card (ISA 428 and ISA 828) is not terminated.